White particulate matter in blood bag: Revisited


Department of Transfusion Medicine, Kovai Medical Center and Hospital, Coimbatore, Tamil Nadu, India

Date of Web Publication22-Mar-2017

Correspondence Address:
Rajeswari Subramaniyan
Department of Transfusion Medicine, Kovai Medical Center and Hospital, Coimbatore, Tamil Nadu
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/GJTM.GJTM_9_17

Rights and Permissions

How to cite this article:
Subramaniyan R. White particulate matter in blood bag: Revisited. Glob J Transfus Med 2017;2:70-1

How to cite this URL:
Subramaniyan R. White particulate matter in blood bag: Revisited. Glob J Transfus Med [serial online] 2017 [cited 2022 Jun 26];2:70-1. Available from: https://www.gjtmonline.com/text.asp?2017/2/1/70/202723

Sir,

White particulate matter (WPM) refers to visible white macroaggregates of varying sizes and shapes observed in the blood units. Although the occurrence of WPM is well known in the past, it is more frequently observed these days. WPM contains mainly platelets and few white blood cells, in some cases, fibrin.[1]

WPM is mostly observed in red blood cell components albeit less frequently encountered in whole blood units. In our center, whole blood unit is used for only massive transfusions. A unit of whole blood stored at 4°C was found to have WPM on day 22. The whole blood was collected in a bag with 49 ml citrate-phosphate-dextrose-adenine-1 and was nonleukoreduced. In accordance with the keys released to the American Association of Blood Banks by American Red Cross Blood Services, we classified the WPM as type I matter, i.e. white small-sized aggregates >50 in number were seen while the bag was laid flat, label side down and undisturbed for 10 min [Figure 1].[2] The other red cell units stored in the refrigerator were not found to have WPM. Samples from the implicated unit were collected in a sterile glass tube, and particles were isolated by sterile 22-gauge needles (using the technique described by Rentas et al.).[3] A crush smear was prepared from the WPM and a hematoxylin and eosin) stain was performed and examined under a bright-field microscope using oil immersion (×1000). The preparation was found to contain platelets and fibrin [Figure 2]. The blood culture was sterile. Complete blood count and lipid profile of the donor were within the normal limits.
Figure 1: Blood bag showing multiple small (starry sky pattern) white aggregates

Click here to view
Figure 2: Smear prepared from the white particulate matter shows clump composed of platelets entangled in a meshwork of fibrin (black arrow). The blue arrow indicates erythrocytes. The pale background is due to serum (H and E, ×1000)

Click here to view


Electron microscopy of these aggregates reveals that they are composed of platelets, fibrin, and WBCs, mixed with cellular fragments, with or without granules.[3] In a random analysis of 356 units with WPM, 12 units were whole blood units containing citrate-phosphate-dextrose,[2] while another study could find WPM only in red cell units but not in whole blood units.[4] Formation of WPM in whole blood units is rare and is attributed to increased adhesiveness of WBCs and platelets. It has been proposed that platelets and white blood cells become sticky during storage and on exposure to cold. Such tendency could also be due to the exposure of phosphatidylserine on the surface of the platelets at the time of apoptosis.[1] By and large, WPM appears to be a normal phenomenon, occurring as a part of storage lesion irrespective of the donor characteristics.[5] Till date, units with WPM have not been vividly associated with any transfusion-related adverse events. Buffy coat removal and leukofiltration prevent the formation of WPM in blood components. Although sufficient evidence is not available that these units could endanger patients' safety, the use of standard filters or leukoreduction filters during transfusion is warranted.[1] It is recommended that all centers should establish their own institutional policy while releasing such units in emergency situations.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
  References Top

1.
McCullough J, Dodd R, Gilcher R, Murphy S, Sayers M. White particulate matter: Report of the ad hoc industry review group. Transfusion 2004;44:1112-8.  Back to cited text no. 1
    
2.
Hillyer CD, Roback JD, Hillyer KL, Josephson CD, Page PL. Description and investigation of white particulate matter in additive solution-1 red blood cell units. Transfusion 2004;44:977-83.  Back to cited text no. 2
    
3.
Rentas FJ, Macdonald VW, Rothwell SW, McFaul SJ, Asher LV, Kennedy AM, et al. White particulate matter found in blood collection bags consist of platelets and leukocytes. Transfusion 2004;44:959-66.  Back to cited text no. 3
    
4.
Patel HD, Byrne KM, Horne M, Leitman SF, Stroncek DF. Factors affecting the formation of white particulate matter in red blood cell components. Transfusion 2005;45:1127-32.  Back to cited text no. 4
    
5.
Simon TL. White particulate matter: This time too much precaution. Transfusion 2004;44:956-8.  Back to cited text no. 5
    


    Figures

  [Figure 1], [Figure 2]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
References
Article Figures

 Article Access Statistics
    Viewed3688    
    Printed118    
    Emailed0    
    PDF Downloaded131    
    Comments [Add]    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]